The Natural Light Tubular Skylight Dimmer is fully assembled
from the factory, but needs to be plugged into a standard
electrical outlet.
The dimmer installation should be completed in conjunction with Steps 13 and 14 from the Tubular Skylight
installation instructions.
1. The dimmer light pipe assembly is 13 1/2“ tall and its height
must be calculated into the overall light pipe length needed in the
attic. The best positioning of the dimmer assembly is at the bottom of
the light pipe going into the home.
- NOTE: If dimmer is installed along with the light kit, the dimmer section must be placed above the light kit section.
2. Join the dimmer assembly with the light pipe section with
the crimped end down. Secure with the supplied tek screws
and seal joints with foil tape.
3. The black control box must hang vertically to function
properly. Using the screw provided, attach it through the
hang hole located at the top of the box to any nearby stud.
Make sure it is positioned above the attic insulation. If there is no
stud nearby, nail a 2x4 vertically to the nearest beam and attach the
control box.
4. Plug electrical cord into outlet.
5. Continue with Step 15 from the Tubular Skylight
installation instructions.
REMOTE CONTROL DIRECTIONS:
The Natural Light Tubular Skylight Dimmer is operated using the provided remote control. Pushing the “ON” button
begins to rotate the dimmer panel and pushing the “OFF”
button will stop the rotation. To achieve varying amounts of
incoming light, adjust the “ON” and “OFF” buttons to move
the dimmer panel until the desired amount of light enters the room (the dimmer panel will rotate 360 degrees).